Meta-analysis of bioabsorbable versus durable polymer drug eluting stents in 20005 patients with coronary artery disease: An update

Catheter Cardiovasc Interv

5 February Feb 2014 12 years ago
  • "Lupi A, Secco GG, Rognoni A, Lazzero M, Fattori R, Sheiban I, Bongo AS, Bolognese L, Agostoni P, Porto I
In comparison with DP-DES, BP-DES significantly reduce LLL and LST rates, without clear benefits on harder endpoints. The efficacy of BP-DES in preserving lumen patency seems larger for sirolimus and novolimus.